- Quick navigation
- Home
- Open menu
- Page content
- Customer service
- Search
- Footer
Mess-Technkik Blatter AG, SCS 0030 Calibration Laboratory
Since 1990, Mess-Technik Blatter AG has been known as a modern and competent company for calibrations and testing activities in the field of length and torque .
Our service
Expertise
Thanks to our highly trained and qualified staff and the use of the latest technology, we perform all tasks relating to normative requirements for test equipment monitoring with a high degree of expertise and professionalism.
Calibration
's calibrations meet all requirements for ISO 9001, ISO13485, 21 CFR Part 820, and ISO/TS 16949 certification. Benefit from our extensive experience with various industry-specific requirements.
Test equipment management
To ensure that we meet the relevant certification requirements, we work with our specially developed and validated management software, guarantee four-language support, and ensure that all relevant data and information can be accessed and queried thanks to web integration.
Personnel
Our highly trained measurement technicians all have basic technical training and several years of experience in the field of measurement technology. In addition, they keep up to date with the latest technology through ongoing theoretical and technical training.
Calibration
Mess-Technik Blatter AG is accredited under accreditation no. SCS No. 0030 in accordance with EN ISO / IEC 17025.
Our range of services includes accredited calibrations as well as some non-accredited calibrations. A detailed overview can be found in the following list.
- Caliper gauges / depth gauges (SCS)
Our calibration instruction MTB/1 A is based on standard DIN 862 with a best possible measurement uncertainty of:
(15+5*L) µm, L in m Micrometers (SCS)
Our calibration instruction MTB/2 A based on standard DIN 863 Part 1 with a best possible measurement uncertainty of: 1.5 µmInternal micrometers (SCS)
Our calibration instruction MTB/3 B based on standard DIN 863 Part 4 with a best possible measurement uncertainty of: (1.5+4*L) µm, L in mDepth micrometers / built-in micrometers (SCS)
Our calibration instruction MTB/4 A based on standard DIN 863 Part 2 with a best possible measurement uncertainty of: (2+3*L) µm, L in mAngle gauges (SCS)
Our calibration instruction MTB/5 A based on standard VDI 2618 Sheet 12 with a best possible measurement uncertainty of: 1′ 30″Dial gauges / precision indicators (SCS)
Our calibration instruction MTB/6 C based on standard DIN 878 / DIN 879 with a best possible measurement uncertainty of: 0.5 µmProbe lever gauges (SCS)
Our calibration instruction MTB/7 A based on standard DIN 2270 with a best possible measurement uncertainty of:
0.5 µmLimit gauges / measuring bolts / test discs Thread measuring wires (SCS)
Our calibration instruction MTB/8 B based on standard DIN ISO 286 with a best possible measurement uncertainty of: 0.25 µm for measuring wires 0.40 µm for other cylindrical test equipment and test discsThread limit plug gauges (SCS)
Our calibration instruction MTB/9 C based on standard DIN 13, ANSI/ASME, B.S.84, BS919 with a best possible measurement uncertainty of: (3+1.5*L) µm, L in mThread gauges (SCS)
Our calibration instruction MTB/10 B based on standards DIN 13, ANSI/ASME, B.S.84, BS919 with a best possible measurement uncertainty of: (3+1.5*L) µm, L in mThroat gauges (SCS)
Our calibration instruction MTB/11 B based on standard DIN ISO 286 with a best possible measurement uncertainty of: (0.6+1.5*L) µm, L in mQuick gauges / quick measuring devices (SCS)
Our calibration instruction MTB/12 A based on standard DIN ISO 286 with a best possible measurement uncertainty of:
15 µmRulers (SCS)
Our calibration instruction MTB/13 A based on DIN 874 with a best possible measurement uncertainty of:
(1.5+0.5*L) μm + A*0.02 L in m (A=display in μm)Angles / hair angles / centering angles (SCS)
Our calibration instruction MTB/14 A based on standard DIN 875 with a best possible measurement uncertainty of:
(1.4+0.5*L) μm + A*0.02 L in m (A=display in μm)Gauge rings (SCS)
Our calibration instruction MTB/15 B with a best possible measurement uncertainty of: 0.3 µm roundness 0.10 µmParallel gauge blocks / setting gauge blocks (SCS)
Our calibration instruction MTB/16 C based on standard DIN EN ISO 3650 with a best possible measurement uncertainty of: (0.06+0.7*L) µm, L in mMarking and height measuring instruments (SCS)
Our calibration instruction MTB/17 B with a best possible measurement uncertainty of: (1.5+2.5*L) µm, L in mTape measures / folding rules / metal rulers
Our calibration instruction MTB/18 A with a best possible measurement uncertainty of: 0.2mmSpirit levels / inclinometers
Our calibration instruction MTB/19 A with a best possible measurement uncertainty of: 0.3 divisionsFlat glass
Our calibration instruction MTB/20 A with a best possible measurement uncertainty of: 0.15 µmForm measurements (gauge pins, gauge rings, and measuring columns) (SCS)
Our calibration instruction MTB/21 B with a best possible measurement uncertainty of: 0.1 µmFlatness on hard stone plates (SCS)
Our calibration instruction MTB/22 C based on standard DIN 876 Part 1 with a best possible measurement uncertainty of: (0.5+0.5*L) µm, L in mOptical measurements (measuring projector)
Our calibration instruction MTB/23 A with a best possible measurement uncertainty of: 5µmSphere (SCS)
Our calibration instruction MTB/24 ATorque wrench / torque screwdriver (fixed) (SCS)
Our calibration instruction MTB/40 C based on standard DIN 6789 with a best possible measurement uncertainty of: 1%Torque wrench / torque screwdriver (SCS)
Our calibration instruction MTB/41 C based on standard DIN 6789 with a best possible measurement uncertainty of: 1%Transducers / Display devices (SCS)
Our calibration instruction MTB/42 C based on standard DIN 6789 with a best possible measurement uncertainty of: 0.4%Measuring probes / display devices
Our calibration instruction MTB/43 A based on standard DIN 878 / DIN 879 with a best possible measurement uncertainty of: 0.5 µmSpring balances / force measuring devices (SCS)
Our calibration instruction MTB/50 A with a best possible measurement uncertainty of: 5%Scales / Weights
Our calibration instruction MTB/51 A with a best possible measurement uncertainty of: 0.2%General visual functional test
Our calibration instruction MTB/60 AExternal calibration / calibration centers
Our calibration instruction MTB/60 A
-------
Calipers, depth gauges, calipers, depth gauges, micrometers, internal micrometers with 3-line contact, internal micrometers with 2-point contact, depth micrometers, built-in micrometers, angle gauges, dial gauges, electronic measuring probes, feeler gauges, limit gauges, individual gauges / test discs, gauge set, Test gauge for micrometers, individual test pins, test pin sets, thread gauges, thread gauges/reject gauges, thread limit gauges, thread gauges, limit rake gauges, internal measuring devices/quick-action gauges, rulers/hairline rulers, angles (flat and stop angles), hair angle, hard stone angle, toolmaker's angle, gauge rings, parallel end gauges, setting end gauges, height gauges, marking gauges, steel rulers / tape measures / folding rulers, inclinometers / spirit levels, flat glass, test plates / hard stone plates, optical measurement, torque wrenches / screwdrivers, precision torque testers, torque testers / torque load cells, spring balances, force gauges
Gallery (4)
Opening times
- Monday *7:00 to 17:00
- Tuesday *7:00 to 17:00
- Wednesday *7:00 to 17:00
- Thursday *7:00 to 17:00
- Friday *7:00 to 17:00
- SaturdayClosed
- SundayClosed
Opening times
- Monday *7:00 to 17:00
- Tuesday *7:00 to 17:00
- Wednesday *7:00 to 17:00
- Thursday *7:00 to 17:00
- Friday *7:00 to 17:00
- SaturdayClosed
- SundayClosed
- Telephone:
- E-Mail:
- Website:
Reviews for Mess-Technik Blatter AG
- English,French,German
- Parking site,Wheelchair-accessible
- Categories
- Instrumentation